Product Description

Air Insulated Switchgear (AIS) uses ambient air as the primary insulation medium for electrical components in medium-voltage (1-52 kV) power distribution networks. Unlike SF6 gas-insulated systems, AIS eliminates potent greenhouse gases, slashing carbon footprints while delivering robust performance. Its modular, open-design construction ensures easy maintenance, compliance with global decarbonization mandates (e.g., EU F-gas bans), and resilience in harsh environments.
Product Parameters
Main technical parameters(circuit breaker cabinet) |
Item |
Unit |
Parameter |
Rated voltage |
kV |
12 |
Rated frequency |
Hz |
50 |
Rated insulation level |
1min power frequency withstand voltage |
Phase-to-ground, phase-to-phase |
kV |
42 |
Insulation breaking |
kV |
48 |
Lightning impulse withstand voltage (peak) |
Phase-to-ground, phase-to-phase |
kV |
75 |
Insulation breaking |
kV |
85 |
1min power frequency withstand voltage (phase-to-ground) of auxiliary/control circuit |
kV |
2 |
Rated current |
A |
630 |
Rated instantaneous withstand current (RMS) |
Main circuit/grounding switch |
kA |
45/4s |
Grounding circuit |
kA |
21.7/4s |
Rated peak withstand current |
Main circuit/grounding switch |
kA |
63 |
Grounding circuit |
kA |
54.5 |
Rated short-circuit breaking current and times |
kA/Time |
25/30 |
Rated short-circuit closing current (peak) |
kA |
63 |
Rated cable charge breaking current |
A |
25 |
Rated operati ing sequence of circuit breaker |
|
O-0.3s-C0.180s-CO |
Mechanical life |
Circuit breaker/insulation switch |
Time |
10000/3000 |
Protection grade |
Sealed enclosure |
|
IP67 |
Switchgear shell |
|
IP4X |
Gas pressure |
Rated gas charge level (20ºC, gauge pressure) |
Mpa |
0.02 |
Minimum gas function level (20ºC, gauge pressure) |
Mpa |
0 |
Seal performance |
Annual leak rate |
%/Year |
≤0.05 |
Main technical parameters (Load switchgear) |
Item |
Unit |
Parameter |
Rated voltage |
kV |
12 |
Rated frequency |
Hz |
50 |
Rated insulation level |
1min power frequency withstand voltage |
Phase-to-ground, phase-to-phase |
kV |
42 |
Insulation breaking |
48 |
Lightning impulse withstand voltage (peak) |
Phase-to-ground, phase-to-phase |
kV |
75 |
Insulation breaking |
85 |
1min power frequency withstand voltage (phase-to-ground) of auxiliary/control circuit |
kV |
2 |
Rated current |
A |
630 |
Rated instantaneous withstand current (RMS) |
Main circuit/grounding switch |
kA |
25/4s |
Groundingcircuit |
kA |
21.7/4S |
Rated peak withstand current |
Main circuit/grounding switch |
kA |
63 |
Groundingcircuit |
kA |
54.5 |
Rated short-circuit closing current (peak) |
Load switch/grounding switch |
kA |
63 |
Rated active load breaking current |
A |
630 |
Rated closed-loop breakingcurrent |
A |
630 |
5% Rated active load breaking current |
A |
315 |
Rated cable charge breaking current |
A |
10 |
Rated active load breaking times |
Time |
100 |
Groundingfault current breaking |
A/Time |
31.5/10 |
Circuit and cable charge current breaking with grounding fault |
A/Time |
17.4/10 |
Mechanical life |
Grcuit breaker/insulation switch |
Time |
10000/3000 |
Protection grade |
Sealed enclosure |
|
IP67 |
Switch gear shell |
|
IP4X |
Gas pressure |
Rated gas charge level (20° C, gauge pressure) |
Mpa |
0.02 |
Minimum gas function level (20°C , gauge pressure) |
Mpa |
0 |
Seal performance |
Annualleak rate |
%/year |
≤0.05 |
Cabinet dimension |
Type |
W |
H |
D |
C |
Top expansion |
420mm |
1950mm |
850mm |
Lateral expansion |
420mm |
2000mm |
V |
Top expansion |
420mm |
1950mm |
Lateral expansion |
420mm |
2000mm |
PT |
Top expansion |
600mm |
1950mm |
Lateral expansion |
600mm |
2000mm |
D |
Top expansion |
420mm |
1950mm |
Lateral expansion |
420mm |
2000mm |








FAQ
Q1: Are you a factory or trading company
A1:We are a factory, and we can guarantee that our price is direct, highly competitive, and cost-effective.
Q2: How does your factory do regarding quality control?
A2: All the products will be 100% checked before the shipment.
Q3: When can I get the price?
A3: Usually we quote within 24 hours after we get your inquiry.
Q4: How could I get a sample?
A4: if you can not buy our product in your local area, we will ship a sample to you. You will be charged a sample price plus all related shipping costs. Express delivery charge depends on the quantity of the samples.
Q5: What is the price of shipping?
A5: Depending upon the port of delivery, prices vary affordable.