Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 600/Piece
Request Sample
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
60
Year of Establishment
2013-12-09
  • Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
  • Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
  • Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
  • Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
  • Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
  • Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
Find Similar Products
  • Overview
  • PRODUCT DETAILS
  • TECHNICAL PARAMETER
  • THE USE OF CONDITIONS
  • COMPANY INFORMATION
  • WOORKSHOP
  • Contact Us
  • Certifications
  • SHIPPING PAYMEANT
Overview

Basic Info.

Model NO.
VS1(ZN63A)E-12
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
ACB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection
Certification
ISO9001-2000, CCC
Transport Package
Wooden Case
Trademark
Zhegui Electric
Origin
Zhejiang, China
HS Code
8537209000
Production Capacity
50pieces/Week

Product Description

Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
PRODUCT DETAILS

VS1E - 12 kv indoor enclosed type column type high voltage vacuum circuit breaker, apply to the rated voltage 7.2 ~ 12 kv, three-phase ac power system frequency 50 hz, widely used in power plants, substations, petrochemical, metallurgy, manufacturing, airports and village, etc., for the protection and control of electrical devices,especially suitable for the rated power flow frequent operation or open circuit of short circuit current place for many times, can be installed in open or stationary air insulated switchgear.Products in line with the GB1984 "AC high voltage circuit breaker", DL/T403 "12~40.5KV indoor AC high voltage circuit breaker ordering technical conditions"
And IEC60694, IEC6227-100 and other related standards.
VS1E-12KV indoor sealed pole column high voltage vacuum circuit breaker adopts advanced APG process, the vacuum arc extinguishing chamber and the main circuit are directly sealed in the epoxy resin pole column to form a sealed insulation mode, representing the world's highest level of high voltage vacuum circuit breaker design and manufacturing.
Note: when the installation mode of this product is replaced by ordinary insulated cylinder, the type of this product is VS1-12.

Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb

Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb

 

TECHNICAL PARAMETER
project units data
The rated voltage kV 12
Rated frequency Hz 50
Rated insulation level Peak rated lightning shock withstand voltage kV 75
Voltage withstand 1min power frequency kV 42
Rated current A 630
1250
630
1250
1250,1600
2000,2500
1600,2000,2500
3150,1000,5000
Rated short circuit breaking current kA   25 31.5 40
Rated short circuit closing current (peak) kA   63 80 100
Rated short circuit duration S 4
Rated sequence of operation   O-0.3s-CO-180s-cO O-180s-CO-180s-CO(40KA)
Rated single/back-to-back capacitor bank breaking current A 630/400
Rated short circuit breaking current breaking times next 30
Closing time ms 30~70
Break-brake time ms 20~50
Mechanical life next 10000
Rated energy storage and operating voltage V AC220/110DC220/110
From contact mm 11±1
Contacts are overspaced mm 3.5±0.5
Average closing speed m/s 0.5~0.8
Average brake speed m/s 0.9~1.2
Contact closing bounce time ms ≤2
Three - phase points, switching is not simultaneity ms ≤2
Main circuit resistance μΩ ≤ 50(630A)≤45(1250A)≤35(1600-2000A)≤25(2500above)
Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb
THE USE OF CONDITIONS

Altitude: not more than 2000m;
Ambient temperature: maximum temperature +40ºC;Minimum temperature -15ºC;
Relative humidity: ≤95%;
Seismic intensity: 8;
Installation place: the place where there is no water drop, fire, explosion danger, serious pollution, chemical corrosion and
violent vibration.

COMPANY INFORMATION

Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb

WOORKSHOP

Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb

Contact Us
Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb

 

Certifications

Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb

SHIPPING PAYMEANT

Zn63A (GTV8) -12/2500A Vs1 Draw-out Indoor Vacuum Circuit Breaker Vcb

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier