Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism

Product Details
Customization: Available
Type: High-voltage
Structure: Three-column Disconnector
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
60
Year of Establishment
2013-12-09
  • Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
  • Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
  • Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
  • Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
  • Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
  • Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
Find Similar Products
  • Overview
  • PRODUCT DETAILS
  • TECHNICAL PARAMETER
  • THE USE OF CONDITIONS
  • RELATED PRODUCTS
  • COMPANY INFORMATION
  • Contact Us
  • FAQ
Overview

Basic Info.

Model NO.
FLN-36
Installation
Indoor High-voltage
Operation
Electric
Grounding Mode
Not Grounding
Movement Mode
Plug-in Type
Number of Poles
Three Pole
Grounding
Un Grounded
Series
Three
Run
Turn the Horizontal
Switching Mode
Single Throw-in
Common Model
Fln36
Structure of Operating
Electric
Certification
ISO, CE, IS9001
Brand
Zhegui
Product Name
Sf6 Load Break Switch
Orign of Place
Zhejiang, China
Related Voltage
up to 12kv
Rated Frequency
50Hz
Rated Current
up to 630A
Rated Capacity
1250kVA
Certificate
ISO CCC
OEM
Offered
MOQ
1PCS
Mechanical Life
500
Transport Package
Wooden Case
Specification
800*490*416
Trademark
Zhegui Electric
Origin
Zhejiang, China
HS Code
8537209000
Production Capacity
50pieces/Week

Product Description

Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
PRODUCT DETAILS

Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
 Sulfur hexafluoride load switch

Description:
*FLN36-12D, FLRN36-12D sulfur hexafluoride load switch, load switch-fuse combination, and loadable cable head load switch are designed and developed by our company by absorbing foreign advanced technology and combining with the operating requirements of our country.
*After comprehensive type test, the product conforms to GB3804 "3~ 63kV AC high voltage load switch", GB16926 "high voltage load switch-fuse combination", IEC60265, IEC60420 standard requirements.
*The product has three positions of arc extinguishing chamber, which is reliable in interlocking , high insulation strength at breakage, large climbing distance design, and the outlet end is protected by voltage sharing protective cover.
* Install cable head type load switch, the outlet end of which is equipped with touch-type cable front connector, the inlet and outlet line is installed with high-voltage cable, and it is equipped with cable branch (connection) box.
* The switch has a special dynamic seal and fixed seal design, reliable seal, and is equipped with pressure gauge in obvious position. It is a new generation of high voltage switchgear equipped with urban power grid for operation monitoring to ensure operation safety.
* This product is suitable for three-phase AC 10KV, 50HZ power systems, industrial and mining enterprises, high-rise buildings, residential areas, pre-installed substation places, used to open and close the load current, fault current, control and protection lines and distribution transformers.
Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
1) Easy to install the fin36-12 SF6 load switch and assembly apparatus are made into a unique unit type (the upper part of the cabinet).and are installed in a stacked way, which greatly reduces the difficulty of the cabinet. Complete set of drawings for the supporting cabinet can be provided
2) Three-position switch has three positions: closing, opening, and grounding
3) There is an observation window on the end face to observe the state of main contact and grounding contact
4) Direct-acting pneumatic arc extinguishing mode
5) The sealing shell is filled with SF6 gas as insulation and arc extinguishing medium.
6) The switch has gas filling nozzle, safety relief valve, and SF6 gas pressure gauge.
7) Manual and electric operation can be selected.
8) It is resistant to the harsh environment and has passed condensation and pollution type tests
9) You can choose the shunt line diagram or over-current release (optional at the same time 
10) Optional moisture switch, 1 on 1 off-4 on 4 off
11) Interlocking between cabinets is optional
12) Pluggable live indication device on the operation panel is optional 
13) It conforms to GB3804 and GB16926 national standards

 

TECHNICAL PARAMETER
 Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism

The technical parameters of the form are for reference only. 
Customized products can consult online customer service!

 
The name of the units data
FLN36-12D FLRN36-12D
The rated voltage   12  12 
Rated frequency   50  50 
Rated current A 630  125 
Load switch rated short - term tolerance current/rated short - circuit duration kA/S 20/3 -
Ground switch rated short-time tolerance current/rated short-circuit duration kA/S 20/2 -
Rated peak tolerance current and rated short-circuit closing current kA 50 125 ( expect )
rated breaking current  Active load breaking current A 630  -
Closed-loop breaking current A 630  -
5% rated active load breaking current A 31.5  -
Turn off the cable charging current A 10 -
Turn off the no-load transformer capacity KVA 1250 1250
Turn off the transfer current A - 1700
Expected short circuit breaking current kA - 50
Rated insulation level 1minl frequency withstand voltage phase, to ground/off KV 42/48 42/48
Lightning shock withstand voltage phase, to ground/off KV 75/85 75/85
Mechanical life   500 500
SF6 rated air pressure (gauge pressure at 20°C)" MPa 0.04-0.05 0.04-0.05
Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
THE USE OF CONDITIONS

Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
Ambient temperature: -15ºC~+40ºC;
Altitude: no more than 1000m;
Relative humidity: the average value of daily relative humidity shall not exceed 95%, the average value of monthly relative
humidity shall not exceed 90%, the average value of daily water vapor pressure shall not exceed 2.2kPa, and the average value of monthly water vapor pressure shall not exceed More than 1.8 kPa;
Ambient air: not visibly contaminated by dust, smoke, corrosive and/or flammable gases, vapors or salt spray; The vibration or ground movement from the outside of the switchgear and control equipment can be ignored;
The amplitude of electromagnetic interference induced in the secondary system shall not exceed 1.6kV.
Special Service Conditions: According to the national standard GBT11022-999 "Common Technical Requirements of High Voltage Switchgear and Control Equipment Standard", the circuit breaker should be operated under normal service conditions. If the working conditions used by the user are different from the normal operating conditions, such as the installation site is over 1000m above sea level, the ambient air temperature exceeds the limit specified in the normal operating conditions or the high humidity where condensation is easy to occur, the user shall consult with the manufacturer and reach an agreement.
 

RELATED PRODUCTS
 

 

Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism
COMPANY INFORMATION


Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism    Zhejiang ZheGui Electric Co., Ltd established in 2013. We are located in Zhejiang with convenient transportation access and developed electrical market. We are group of private enterprises that hold the production license issued by the former ministry of energy and ministry mechanical and electrical engineering. 
    The company has nearly 60 million fixed assets and more than 60 employees, covering 23133 square meters. We are specialized in R&D production of complete switchgear of high and low voltage equipment such as prefabricated substation, distribution cabinet/box, drawer cabinet, ring network cabinet, inflatable cabinet, etc. 
    We owns three CNC bending machine, CNC shearing machine, CNC laser cutting machine and a series of advanced production equipment to further optimized the product structure and improve the efficiency of production. After nearly 7 years of development, it has passed ISO 9001-2000 quality system certification. All items produced by our own factory, so our advantages are: reliable quality and reasonable price. Gather the world's energy to delight your business. It's honorable for Zhegui to share your progress, brilliance and success!

Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism

Contact Us

Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism

 

FAQ

Sf6 Load Break 11kv 12kv 3 Phase Load Break Disconnector Switch Mechanism

Q1: Are you a factory or trading company
A1: We are a factory, we can guarantee our price is first-hand, very cheap and competitive.

 

Q2: How does your factory do regarding quality control?
A2: All the products will be 100% checked before the shipment.

 

Q3: When can I get the price?
A3:Usually we quote within 24 hours after we get your inquiry.

 

Q4: How could I get a sample?
A4: if you can not buy our product in your local area, we will ship a sample to you. You will be charged a sample price plus all related shipping costs. Express delivery charge depends on the quantity of the samples.

 

Q5: What is the price of shipping?
A5: Depending upon the port of delivery, prices vary.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier